Condition Possible Cause Corrective Action
Forms are wrinkled or badly
folded.
Forms not feeding squarely
against form stop(s).
Adjust the form stop(s) to
squarely deflect the forms;
ensure the stop setting is
identical on both scales.
See page 16.
Dirty folding rollers. Clean folding rollers.
Fold plate form stop(s)
adjusted improperly.
Check and adjust the
position of the fold plate
form stop(s). See page 16.
Folding rollers adjusted
improperly or worn; sealing
rollers adjusted improperly.
Contact your Pressure Seal
distributor for advice.
Two or more forms are
feeding into the folder
together.
Forms in stack are sticking
together.
Fan form stack and reload
forms.
Poor air flow on feed bed. See page 22.
Separator block not set up. See page 22.
5. Operation Errors PS 600
Page 38 22-01-03 Iss. B.