Condition Possible Cause Corrective Action
Forms are mishandled in the
folder or damaged during
sealing.
Dirty folding rollers. Clean rollers with cleaning
solution. See page 39.
Folding roller adjusted
improperly or worn; sealing
rollers adjusted improperly.
Contact your Pressure Seal
distributor for advice.
Forms not sealing. Pressure on sealing rollers
is relieved.
Reset pressure on the
sealing rollers. See page 34.
Forms in wrong way round. Replace forms correctly.
Forms have been incorrectly
stored, or are older than
their shelf life (one year).
Use fresh forms.
Fold plate form stop(s)
adjusted improperly causing
poor registration of adhesive
strips.
Check and adjust position of
the fold plate form stop(s).
See page 16.
Sealing rollers adjusted
improperly.
Contact your Pressure Seal
distributor for advice.
Forms are misfeeding. In-feed tray form guides are
set too tight or too loose.
Set the guides so there is
just enough clearance to
allow the form to move freely
between the guides.
Debris in folding plates;
folding plates not installed
properly; fold plate form
stop(s) adjusted improperly.
Remove debris; properly
install folding plates; check
and adjust the position of
the fold plate form stop(s).
Separator block not set up
correctly.
Contact your Pressure Seal
distributor for advice.
Vacuum not set up properly. See page 22.